The DL-10T Cryogenic Excess Flow Control Valve is a highly specialized safety component designed for use in LNG (Liquefied Natural Gas) tank trucks. This valve is engineered to provide precise flow control and protection in cryogenic conditions, ensuring the safe and efficient transport of LNG. 
Type:
Availability:
Quantity:
  • DL-10T

  • Feilun

Product Paremeters

Type Major Overall & Connection Dimensions(mm)
L L1 L2 M M1 D D1 D2 J
DH-10T 16 72 14 M27*2 NPT3/8 ∅16 ∅22 ∅10 90°

Product Details

DL-10T












Nominal Pressure:4.0MPa

Nominal Diameter:10mm

Design Temperature:-196℃~+85℃

Suitable Media:LNG、LO2、LN2、LAr

Body、Ball:Stainless Steel












The DL-10T Cryogenic Excess Flow Control Valve is a highly specialized safety component designed for use in LNG (Liquefied Natural Gas) tank trucks. This valve is engineered to provide precise flow control and protection in cryogenic conditions, ensuring the safe and efficient transport of LNG. Built to handle the extreme low temperatures and high pressures that are typical in LNG transport, the DL-10T valve is critical in maintaining the integrity and safety of tank trucks used in the transportation of cryogenic liquids.

One of the standout features of the DL-10T Cryogenic Excess Flow Control Valve is its automatic shut-off mechanism. This safety feature is designed to close the valve instantly if the LNG flow exceeds a pre-determined limit due to a rupture, leak, or system failure. By preventing uncontrolled LNG discharge, the DL-10T valve plays a crucial role in reducing the risk of accidents, protecting both the cargo and the tank truck. This precision-engineered flow control capability helps maintain safe operations under the demanding conditions of cryogenic transport.

The DL-10T valve is constructed from durable materials specifically chosen for their ability to perform in cryogenic environments. Its corrosion-resistant build ensures long-lasting performance, even when exposed to extreme cold and harsh operational conditions. This durability makes the DL-10T an ideal solution for LNG tank truck manufacturers and operators who require a valve that offers both reliability and longevity. Its rugged design reduces the frequency of maintenance and extends the operational life of the valve, lowering long-term maintenance costs.

With its compact size, the DL-10T Cryogenic Excess Flow Control Valve is designed for easy integration into LNG tank truck systems. Its streamlined design allows for straightforward installation without the need for extensive modifications, making it an efficient solution for both new builds and retrofits. The valve’s user-friendly design also facilitates easy inspection and maintenance, minimizing downtime and ensuring that LNG transport operations remain as efficient as possible.

Meeting stringent industry standards, the DL-10T valve ensures compliance with safety regulations specific to cryogenic and LNG transport applications. Its ability to automatically shut off flow in the event of excess flow conditions is a critical safety feature that enhances the overall safety profile of LNG tank trucks. This valve not only prevents hazardous conditions such as leaks or overflows but also helps operators meet regulatory requirements, ensuring the protection of both personnel and the environment.

Designed to perform reliably under extreme conditions, the DL-10T Cryogenic Excess Flow Control Valve is ideal for use in a variety of LNG transport scenarios, including long-distance trucking and distribution networks. The valve’s ability to effectively control and manage LNG flow makes it a valuable asset for operators seeking to optimize the safety and performance of their cryogenic systems. By preventing excess flow, the DL-10T valve reduces the risk of damage to equipment and ensures the safe transport of LNG.

In summary, the DL-10T Cryogenic Excess Flow Control Valve is a vital component for LNG tank trucks, offering superior safety, durability, and ease of maintenance. Its automatic shut-off mechanism and precision-engineered flow control ensure that LNG is safely transported without the risk of uncontrolled discharge. Built to withstand the rigors of cryogenic environments, the DL-10T valve provides reliable performance over the long term, making it an essential choice for LNG operators seeking to enhance safety and efficiency in their transport systems.

[NOTED]

1、The material for producing the valve is the raw material processed by the factory itself. Through the smelting furnace, the raw materials such as electrolytic copper and lead plate are produced into HPb59-1 (Brass) higher than the national standard, and then through special extrusion, cutting, processing, cleaning and other equipment Produce the required parts. Therefore, source quality control is a vital part of the entire quality management system.

2、We are self-produced and sold, have a large inventory and low MOQ(1pcs).

3、We have related cryogenice valves certificates.

Previous: 
Next: 
Danyang Feilun Gas Valve Co., Ltd. established in 2001, located in a historic town Yanling in Jiangsu, China. It is a professional valve manufacturer with more than 200 employees, including dozens of technical engineers.

Quick Links

Contact Us

 sales@yixuan66.com 
 +86-511-86862993
 +86-13861384368
 +86-13861384368
 21 Dongjin Rd., Yanling Town, Danyang District, Zhenjiang City, Jiangsu, China
 
Leave a Message
Contact Us
Copyright ©  2023 Danyang Feilun Gas Valve Co., Ltd. All Rights Reserved. Privacy Policy | Sitemap Support By Leadong